Industrial cable trays, wire ducts, junction boxes and conduit systems — designed for straightforward selection, reliable performance and fast delivery to 28 countries.
From simple wire duct to complete plant-wide cable tray systems — straightforward selection, consistent quality, delivered fast.
Steel and aluminum cable trays with hot-dip galvanized, pre-galvanized or powder-coat finish. IP rating-ready installations for widths 50–600mm. IEC 61537 type-tested.
Inquire Now
PVC and halogen-free slot wire ducts for panel wiring. Available in 25×25mm to 100×100mm profiles. Easy cable routing, snap-fit lids, 1-meter standard lengths.
Inquire Now
Polycarbonate and steel junction boxes from IP54 to IP67 protection. Paired with metric and NPT cable glands in brass, stainless and nylon — covering 5–52mm cable diameters.
Inquire Now
Rigid and flexible conduit in PVC, galvanized steel and stainless steel. Complete fitting range: couplings, bends, junction boxes and locknuts. Metric EN 50086 and trade size IPS available.
Inquire Now
Push-in, screw and spring-cage terminal blocks rated to 1000V / 4–95mm² cross-section. Compatible with standard DIN TS 35 rail. Color coding for quick circuit identification.
Inquire NowTell us about your application — cable size, installation environment, IP requirement — and we'll recommend the right solution.
Chat with an Expert
We believe cable management should be both reliable and responsible. Our ISO 14001-aligned manufacturing processes minimize waste, and our RoHS-compliant materials ensure zero restricted substances in every product we ship.
Extended product lifespans and high-quality recyclable steel and aluminum mean our cable trays and wire ducts deliver value for 15+ years — reducing lifecycle replacement costs and landfill waste.
Different environments demand different solutions. NexaFlow products cover the full spectrum of industrial and commercial cable management needs.
Engineers and procurement managers across manufacturing, construction and data centers trust NexaFlow.
Common questions from engineers, procurement teams and contractors. Don't see your question? Ask us directly.
Our perforated and ladder cable trays are IEC 61537 type-tested in load classes A (50 kg/m), B (100 kg/m), C (150 kg/m) and D (200 kg/m), with span configurations from 1,000mm to 3,000mm. Full load tables are available for download.
Yes. We offer hot-dip galvanized (HDG) and 316L stainless steel cable trays for coastal, marine and chemical environments, plus UV-stabilized PVC conduit and IP54–IP67 junction boxes for outdoor installations.
Over 2,000 standard SKUs are held in stock for same-day picking and 3–5 working day delivery to most major markets. We also offer an express 48-hour dispatch program for urgent project requirements.
All NexaFlow cable management products carry CE Marking under the applicable EU directives and are fully RoHS 3 and REACH compliant. ISO 9001:2015 certification covers our entire manufacturing and quality management process.
Absolutely. We provide free product samples for qualified projects — just submit a sample request with your application details and we'll ship the most relevant items for evaluation, typically within 5 working days.
Yes — we accommodate custom widths, lengths, perforations and surface finishes including powder coat RAL colors and additional hot-dip galvanizing thicknesses. Minimum order quantities apply; contact us for a quotation.
Tell us about your project and we'll recommend the right products, send free samples, and provide a fast quote — no minimum order for first enquiries.