Siemens Contactor Guide: What Is an Electrical Contactor and Why 22E Isn’t Enough

Reading a forum thread about a Kawasaki oil filter 49065 cross reference taught me something about industrial control gear. Not about oil filters—about how people choose parts when the part number is incomplete.

The thread had the usual list of substitute filters. Then someone asked: What is the bypass valve pressure on the 49065? The thread went quiet. Nobody knew. The cross-reference was based on visible dimensions, not on the specs that actually matter for a filter. That is exactly the pattern I see when people choose a Siemens contactor.

I’m a quality manager at an industrial controls distributor. Every week, I review contactor orders before they ship. In 2024, I rejected about 7% of first-time order lines because the selected part did not match the application data sheet. Wrong coil voltage, missing auxiliary contacts, or a contactor relay where a power contactor was needed. The mistakes were rarely made by one careless person. They were the natural result of using shorthand when the spec needed detail.

What is an electrical contactor?

Let’s start with the basics. An electrical contactor is a remotely controlled switch for power circuits. Inside the contactor, an electromagnetic coil pulls a set of contacts closed when the coil is energized. When the coil is de-energized, spring force opens them. That simple action lets a small PLC output or a push button manage a much larger motor load.

The key word is switch. A contactor is designed to switch loads on and off under normal conditions. In a motor starter, it is usually paired with an overload relay. The overload relay protects the motor from sustained running current. The contactor does the switching. They are separate functions, and that distinction matters.

Siemens has two separate product groups that people often confuse: power contactors and contactor relays. A Siemens contactor relay—often from the 3TH or 3RH family—has multiple auxiliary contacts and is used in control circuits. It switches control signals, not motor current. A power contactor like the Sirius 3RT family switches the main circuit. You can use a contactor relay to pilot a power contactor, but you cannot substitute one for the other.

Under IEC 60947-4-1, contactors are classified by utilization categories. The one you will see most often is AC-3, which covers starting and stopping squirrel-cage motors. If your application involves reversing or jogging, you may need an AC-4 rating. I mention this because a lower-rated contactor can appear to work for months before the contacts fail.

Why a dual pole circuit breaker is not the answer

Every so often someone lands here searching for a dual pole circuit breaker. They’re usually trying to solve a switching problem. Here’s the distinction: a circuit breaker is a protective device. It interrupts fault currents and protects wiring. A contactor is a switching device. It makes and breaks a load circuit repeatedly under control.

A dual pole breaker upstream of a Siemens contactor is normal practice. Using that breaker to switch a motor on and off is not. The breaker can handle overcurrent, but it is not designed for frequent operation, and it does not have a control coil. If you are building a motor starter, you need a contactor and an overload relay. The breaker is there for protection, not control.

The real problem: part number shorthand like Siemens 22E

Now we get to the part that I wish more people took seriously. In a maintenance store, you might hear someone ask for “the Siemens 22E contactor.” I have heard that exact phrase. I understand what they mean: they want a legacy 3TF contactor in that frame size. But the phrase 22E does not tell you the coil voltage. It does not tell you whether the coil is 50 Hz or 60 Hz. It does not tell you whether the auxiliary contact block is integrated or add-on. The complete catalog number, printed on the side of the device, does.

I have had to turn away orders because the only description was “Siemens 22E contactor.” The person on the other end was frustrated, but the next morning they found the nameplate and we shipped the right part. The nameplate is the source of truth. The shorthand is not.

This is also where the Kawasaki oil filter 49065 cross reference mental model falls apart. With a filter, the thread size and height can be enough to get you close. With an electromechanical contactor, you need the coil voltage, the utilization category, the auxiliary contact layout, the terminal capacity, and the approvals. A cross-reference might get you to a part family. It will not get you to a safe, reliable installation by itself.

What happens when the wrong part ships

Let me tell you what a specification error actually costs. In Q1 2024, we reviewed a panel builder’s spare parts order for 32 contactors. The BOM said “Siemens contactor relay” where the engineering drawings specified a power contactor with a 24 V DC coil. The ordering system accepted it because both descriptions looked similar. The order arrived, went into a control panel, and the first test cycle did not close. The damage was not a factory trip—it was a commissioning halt. The panel had to be reworked, the wrong units returned, and the right contactors air-freighted. Total extra cost was roughly $7,400, and the project missed its launch window.

One of my biggest regrets from my earlier years: not photographing a contactor nameplate before a maintenance lead walked me to the spare parts store. He was absolutely sure the part number was ‘the usual one.’ The story he remembered was wrong. We installed a 220 V AC coil into a 380 V AC panel, and the coil overheated in testing. If I had spent 30 seconds taking a photo, the second shutdown would not have happened.

The most frustrating part is that these failures are not random. They come from the same pattern: someone sees a familiar short code, assumes the rest of the specification is unchanged, and makes that assumption the basis of a purchase. Then the system confirms the assumption because the wrong part number happens to be in the same product family.

What to check before you buy

Here is the short version of the review process I use. It doesn’t replace a data sheet, but it will prevent most of the errors I see. Before you order a Siemens contactor, check these five things. I am deliberately keeping this list short; if a checklist is long, people skip it.

  • Coil voltage and frequency: AC 24 V, 110 V, 230 V, 400 V, DC 24 V, and 50/60 Hz versions are common. Match the control circuit exactly.
  • Rated operational voltage and current: Look at the contactor’s utilization category (AC-3, AC-4) and the motor full-load current, not the breaker size.
  • Auxiliary contacts: How many N/O and N/C do you need? Do you need early break, mirror contacts, or safe isolation?
  • Conductor termination: Rail size, screw or spring terminals, and connection capacity. A contactor that fits electrically but not physically can still fail an inspection.
  • Approvals and standards: Check IEC 60947-4-1, UL 60947-4-1, or the relevant regional approval for the end market.

The bottom line

Look, I don’t want to make this sound harder than it is. If you already have the full catalog number and the data sheet, buying a Siemens contactor is straightforward. The hard part is deciding whether you trust the half-specs in front of you. A cross-reference like the Kawasaki oil filter 49065 cross reference can be a starting point, but it should never be the ending point. For a contactor, the ending point is a verified part number, an approval that matches your market, and a delivery date you can rely on.

This is why I am willing to pay for certainty. Not because I like rush fees. Because an hour of unplanned downtime in a process plant costs more than any difference in component pricing. I have seen that line item on a repair bill. I have also seen the blank face of someone who chose a part based on a cross-reference guess. The extra cost of being certain is small. The cost of not being certain can be your whole schedule.

That approach reflects my side of the supply chain—a distributor with access to Siemens technical data. If you are an OEM doing high-volume panel production, your reorder process will be different. But the principle is the same. As of Q1 2025, the Sirius 3RT range is the current Siemens power contactor family; legacy 3TF and 3TH parts are still available for many frame sizes, but verify availability before you build your maintenance stock.

author avatar
Jane Smith

I’m Jane Smith, a senior content writer with over 15 years of experience in the packaging and printing industry. I specialize in writing about the latest trends, technologies, and best practices in packaging design, sustainability, and printing techniques. My goal is to help businesses understand complex printing processes and design solutions that enhance both product packaging and brand visibility.